Harrer & Kassen
Catalogue 2007-04
Processmeasurement Measure Instruments Sensor Systems Microwave Technique NIR-Spectrometer
Catalogue 2007-04 / 3rd Edition
www.harrerkassen.com
[email protected] T:+49-(0)7084-928410
Am Heschen 6
F:+49-(0)7084-928429
D-75328 Langenbrand
copyright Harrer & Kassen GmbH 2007 / all rights reserved
The Way is the Target Lao Tse
Harrer & Kassen
Catalogue 2007-04
Page
Content: 1
Application / Business field
1.1 1.2 1.3
Processmeasurements Procedures of Measurement Industry Applications
2
Evaluation units
2.1 2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 2.2 2.2.1 2.2.2 2.2.3 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.4 2.5 2.5.1 2.5.2
HK1 HK1-M HK1-Mp HK1-Mc HK1-Mc-LAB HK1-C HK2 HK2-M HK2-C HK2-F HK4 (NIR-spectralyser) HK4-1 HK4-2 HK4-3 HK4-mobile LAB HK5 HK6 HK6-C HK6-F
3
5 5 6 9
11 11 11 12 13 14 15 15 15 16 16 17 17 18 19 20 20 22 22 22
3
Components
3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6
Sensors / Antennas PT100 Pinantennas Pinantennas-Cleaning 3A-Spiralantennas Short 3A-Pinantennas Mini-Spiralantennas Spiralantennas Hornantennas 10/24GHz-Sensors NIR-Sensor / Halogenlamp Measure Cells 3A-Flowcell (for 3A-Spiralantennas) and welding flange 3A-Flowcell (for short 3A-Pinantennas) and welding sockets Flowcell (for Mini-Spiralantennas) and welding sockets 3A-Flowcell (for NIR-Reflection) 3A-Flowcell (for NIR-Transmission) 3A-Tankcell (für NIR-Reflection)
4
Devices / Spareparts
4.1 4.1.1 4.1.2 4.1.2.1 4.1.2.2 4.1.2.3 4.1.3 4.1.4 4.1.5 4.1.6 4.2 4.2.1
Devices Remote Control Cable HF-Cable Standard-Cable Optical Fiber Swiffle-Flange Stainless-Steel-Housing Distance-Lasersensor Laboratory-Measure-Device Spare Parts Halogen Bulbs
copyright Harrer & Kassen GmbH 2007
23 23 23 23 24 24 24 25 25 25 26 26 26 27 27 28 28 29 29
30 30 30 30 30 30 31 31 31 31 32 32 32
3
all rights reserved
Harrer & Kassen
Catalogue 2007-04
5
Technical Data
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14
HK1-M HK1-Mp HK1-Mc HK1-C HK2-M HK2-C HK2-F HK4-1 HK4-2 HK4-3 HK4-mobile LAB HK5 HK6-C HK6-F
33 33 34 35 36 37 38 39 40 41 42 42 43 44 45
6
Operation / Commissioning
46
7
Article Numbers
48
8
Conditions for Sale and Trade / Imprint
52
9
Technical Annex
53
copyright Harrer & Kassen GmbH 2007
4
all rights reserved
Harrer & Kassen
1
Catalogue 2007-04
Application / Business field The Harrer & Kassen GmbH was established 1996 and is located in the northern Black Forest in Langenbrand. We are experts in the process measurement field.
We are developing and producing progressive and advanced instruments at the latest state of the art. High performance, high measurement accuracy and high availability of the instruments made us to a leader in the supply of process measurement technology. 1.1
Processmeasurements
Matched to the engineering processes in the different industries, various procedures of measurement are in use in dependance of the technical material transport and the product to be analysed. The material to be analysed can be transported in pipes, vessels, silos, tanks or conveyer belts and the product can be solid, liquid or gaseous. For the quality insurance the products are under measurement to define and monitor concentration, moisture, limit values and organic components.
density, concentration
measurement of solids in water
moisture
measurement of the water content in different solids
limit values
measurement of the min-/max levels of liquid materials
organic components
detection of one or more organic components in an organic mixture
copyright Harrer & Kassen GmbH 2007
5
all rights reserved
Harrer & Kassen
1.2
Catalogue 2007-04
Procedures of Measurement
NIR In the NIR-measurement technology the surface of the product is illuminated by white halogen light. An optical fiber sensor transfers the data, measured after the transmissive or reflective principle, to the diode array. A significant higher resolution can define all molecules with an absorption line in the spectrum of measurement. The evaluation with diode arrays realize the measurement of every organic component in the detected spectrum. Mainly this are CH-, NH- and OH-molecules. The simultaneous measurement of up to 5 organic components is realized with an accuracy of 2 nanometers through a high resolution diode array. The spectral detection in the spectrometer is defined in the wavelength range between 600 and 2500 nanometers.
Modular structure of evaluation-unit and NIR-sensor. Both are connected by an optical fiber whith a max. length of up to 100 meters. The optical fiber is protected through a coating of stainless steel and contains no organic components, which could have any influence to the result of the measurement.
NIR-sensor with halogenlamp NIR-detections are alternativly performed with transmission or reflection. At the reflection principle, the product is illuminated with white halogen light. The reflected NIRpart is detected by the NIR-sensor and transferred to the diodearray via an optical fiber. NIR-reflection principle At the transmission principle the white halogenlight streams through the product. This only works, if the product is made of transparent material. The halogenlight is received by the NIR-sensor (at the opposite side of the lamp) and is transferred to the diodearray via an optical fiber. The measurements are performed normally at tanks, silos, mixers and pipes. Different NIR-transmission principle flowcells and flanges with special glasswindows are available also for the requirements in the food industry. The measurement cannot be influenced by environmental light or colour. The NIR-reflection measurement at conveyer belts only should be realized, if the product provides a homogenious and plain structure of the surface.
copyright Harrer & Kassen GmbH 2007
6
all rights reserved
Harrer & Kassen
Catalogue 2007-04
Microwave Measurement In the microwave measurement an electromagnetic wave with low energy is generated and via an antenna integrated into the product. This wave spreads out in the product in dependance of the electrical characteristics. A second antenna receives this wave. Energy and phase of the received wave are indicators for the watercontent, the material concentration and density in the product. MW-measurements are qualified because of high stability and a very short feedback time. Measurements at conveyer belts or nonconductive tanks are operating without direct contact and can be mounted outside of the process equipment. In case of metallic tanks the sensors are inserted together with a flange in the wall.
Provision of the latest digital microwave technology at 2,45GHz or 10/24GHz. In dependence of the measurement, different sensorsystems can be used alternativly.
pinantennas:
short pinantennas:
spiralantennas:
mini-spiralantennas:
hornantennas:
3A-spiralantennas:
10/24GHz-sensors:
copyright Harrer & Kassen GmbH 2007
7
all rights reserved
Harrer & Kassen
Catalogue 2007-04
Highfrequency Measurement In the highfrequency measurement an electromagnetic wave with low energy is generated and via an antenna integrated into the product. This wave spreads out in the product in dependance of the electrical characteristics. A second antenna receives this wave. Energy and phase of the received wave are indicators for the watercontent in the product. HF-measurements are qualified because of high stability and a very short feedback time. Measurements at conveyer belts or nonconductive tanks are operating without direct contact and can be mounted outside of the process equipment. In case of metallic tanks the sensors are inserted together with a flange in the wall.
Radiometric Measurement Radiometric systems are used for non contact and continuous measurements with a radioactive spot beamer and a nuclear detector at tanks or pipes. In the radiometric measurement technology a nuclear detector is used to analyse the intensity of gamma-rays, generated from a radioactive spot beamer. The reduction of the intensity of the gamma rays, infected from the product, is the scale for the detection of density or concentration. Radiometric systems are operating without direct contact and can be mounted outside of the process equipment. They are free from wear and tear and the physical or chemical properties of the product have no influence to the measurement.
copyright Harrer & Kassen GmbH 2007
8
all rights reserved
Harrer & Kassen
1.3
Catalogue 2007-04
Applications
We do measure online in the process, not offline in the laboratory! With our microwave instruments and our NIR spectrometer we are present in allmost every branch in a large number of industries: Food Industry food mill products dairy products sweets bread production frozen food tobacco products pet food sugar production
Freshfood Industry meat poultry fish Drinks Industry breweries soft drinks wine spirits coffee & tea
dairy products
TS-measurement lab ferment cheese curd - soft cheese - sliceable cheese - hard cheese cream cheese - curd cheese - cottage cheese milk products - jogurt - consumpt. milk - butter etc.
Chemical Industry primary industry domestic chemicals pharmacy paper process Construction Ind. horticulture paints building material building techniques
measurement of fat, water, protein milk products milkpowder products - milk powder - jogurt - consumption milk - cream powder - butter etc. - jogurt powder
food
measurement of fat, water, protein agglomerated and non agglomerated powders for instant foods, soups and sauces
frozen food
measurement of fat, fat acid, water, protein convenience products as pasta, meatand fish fastfood, Chinese / Thai food
sweets
measurement of fat, water chocolate-, sweets-, praline production
pet food
measurement of fat, water, protein meat und fodder
copyright Harrer & Kassen GmbH 2007
9
all rights reserved
Harrer & Kassen
Catalogue 2007-04
sugar production BRIX-measurement sugar based raw material - sugar beets - sugar cane
meat measurement of fat, water, creatin and collagen (BEFFE) sausage meat for the production of - raw sausage - boiled sausage - meat paste - black pudding - frying sausage - meatballs - hash - pastry
poultry
measurement of fat, water, protein sausage meat for the production of pastry etc.
breweries
measurement of water, ethanol, yeast top-fermented beers and ales etc.
spirits
measurement of ethanol liqueur and brandy
pharmacy
measurement of water, protein, amino acid agglomerated and not agglomerated powders for the medicine production
paper
TS-measurement (density) cellulose-, paper-, boardproduction rag paper processing measurement of water, ash, shade of grey cellulose, paper measurement of water in thin layers paper, board, cardboard
primary industry
measurement of water chipboard production
primary industry
measurement of water concrete- and cement production
copyright Harrer & Kassen GmbH 2007
10
all rights reserved
Harrer & Kassen
Catalogue 2007-04
2 2.1
Evaluation units HK1 Latest digital microwave technilogy at 2,45 GHz. The microwave instrument HK1 is available in 4 product versions: - HK1-M modular - HK1-Mp modular paper - HK1-Mc modular cheese - HK1-C compact
2.1.1
HK1-M
HK1-M
range of application measurement of concentration and water content in the food- , primaryand chemical industry.
design aluminium pressure casting housing h x w x d: 200 x 230 x 110mm HF-cable 2 x 2m evaluation unit HK1-M functionality / sensor systems 2 pinantennas HK1-M1HK1-M1-
PAN-6506 PAN-8006
pinantennas (with PT100 and flange DN65)
HK1-M1-
3SA-3AFC
3A-spiralantennas (for 3A-flowcell)
HK1-M1-
3SP-FLC1
short 3A-pinantennas (for 3A-flowcell)
HK1-M1-
MSA-FLC2
mini-spiralantennas with sockets (for flowcell)
HK1-M2-
SPA-0000
spiralantennas
HK1-M2-
HOA-0000
hornantennas
pinantennas (with PT100 and flange DN80)
2 3A-spiralantennas
2 short 3A-pinantennas
2 mini-spiralantennas
2 spiralantennas
2 hornantennas
copyright Harrer & Kassen GmbH 2007
11
all rights reserved
Harrer & Kassen
2.1.2
HK1-Mp
Catalogue 2007-04
HK1-MP
range of application measurement of density in the paper industry
design aluminium pressure casting housing h x w x d: 177 x 177 x 100mm HF-cable 2 x 2m evaluation unit HK1-Mp functionality / sensor systems 2 pinantennas PAN-8006
pinantennas (with PT100 and flange DN80)
3SA-WFL1
3A-spiralantennas (for welding flanges)
MSA-FLC2
mini-spiralantennas with sockets (for flowcells)
2 3A-spiralantennas
2 mini-spiralantennas
copyright Harrer & Kassen GmbH 2007
12
all rights reserved
Harrer & Kassen
2.1.3
HK1-Mc
Catalogue 2007-04
HK1-MC
range of application total solids- and watercontentmeasurement for the cheeseproduction dairy and cheese factories. design aluminium pressure casting housing h x w x d: 200 x 230 x 110mm stainless steel box 300 x 500 x 170mm distance-lasersensor HF-cable 2 x 2m evaluation unit HK1-Mc functionality / sensor systems 2 spiralantennas SPA-CH01
spiralantennas
1 stainless steel box
copyright Harrer & Kassen GmbH 2007
13
all rights reserved
Harrer & Kassen
2.1.4
HK1-Mc-LAB
Catalogue 2007-04
HK1-MC
range of application total solids- and watercontentmeasurement for the cheeseproduction dairy and cheese factories. design aluminium housing h x w x d: 130 x 390 x 210mm distance-lasersensor HF-cable 2 x 2m
Auswerteeinheit HK1-Mc-LAB
functionality / sensor systems 2 spiralantennas LAB-CH02
spiralantennas
1 laboratory-measure-device (stainless / teflon) HKD-CH-TEF-0001
copyright Harrer & Kassen GmbH 2007
14
all rights reserved
Harrer & Kassen
2.1.5
HK1-C
Catalogue 2007-04
HK1-C1
range of application measurement of concentration and water content in the food- , primaryand chemical industry. density measurement paper industry. design aluminium pressure casting housing h x w x d: 177 x 177 x 100mm
evaluation unit HK1-C functionality / sensor systems 2 integrated pinantennas PAN-8006
pinantennas (with PT100 and flange DN80)
2.2
HK2 Latest digital microwave technilogy at 2,45 GHz. The microwave instrument HK2 is available in 3 product versions: - HK2-M modular - HK2-C compact - HK2-F field
2.2.1
HK2-M
HK2-M1
range of application concentration measurement BRIX in the sugarindustry
design aluminium pressure casting housing h x w x d: 177 x 177 x 100mm HF-cable 2 x 2m evaluation unit HK2-M functionality / sensor systems 2 pinantennas PAN-6506
pinantennas (flange DN65)
PAN-6506
pinantennas (with cleaning and flange DN65)
2 pinantennas
copyright Harrer & Kassen GmbH 2007
15
all rights reserved
Harrer & Kassen
2.2.2
HK2-C
Catalogue 2007-04
HK2-C1
range of application concentration measurement BRIX in the sugarindustry
design aluminium pressure casting housing h x w x d: 177 x 177 x 100mm
evaluation unit HK2-C functionality / sensor systems 2 integrated pinantennas PAN-6506
2.2.3
HK2-F
pinantennas (with NTC and flange DN65)
HK2-F1
range of application concentration measurement BRIX in the sugarindustry
design aluminium pressure casting housing h x w x d: 177 x 177 x 100mm no softkeys evaluation unit HK2-C functionality / sensor systems 2 integrated pinantennas pinantennas (with NTC and flange DN65)
OPE-6506
1 remote control remote control with 10m connection cable
copyright Harrer & Kassen GmbH 2007
16
all rights reserved
Harrer & Kassen
Catalogue 2007-04
2.3
HK4 (NIR-spectralyser) Latest NIR-technology with diode array. The spectrometer HK4 is available in 3 product versions: - HK4-1 600nm - 1100nm - HK4-2 1200nm - 1700nm - HK4-3 1700nm - 2500nm
2.3.1
HK4-1
HK4-10
range of application Measurement in % of 3 organic constituents, through spectral absorption of all molecules of the CH-, NH- and OHcompounds. spectral range 600nm - 1100nm design aluminium pressure casting housing h x w x d: 230 x 280 x 110mm evaluation unit HK4 NIR-4BFR
functionality / sensor systems 1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / reflection
NIR-4SFR
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / reflection
NIR-4BFT
1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / transmission
NIR-4SFT
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / transmission
NIR-4BTR
1 NIR-sensor halogen lamp 4B black enodized 3A-tankcell DN50 / reflection
NIR-4BTR
1 NIR-sensor halogen lamp 4S stainless steel 3A-tankcell DN50 / reflection
copyright Harrer & Kassen GmbH 2007
17
all rights reserved
Harrer & Kassen
2.3.2
HK4-2
Catalogue 2007-04
HK4-20
range of application Measurement in % of 4 organic constituents, through spectral absorption of all molecules of the CH-, NH- and OHcompounds. spectral range 1200nm - 1700nm design aluminium pressure casting housing h x w x d: 230 x 280 x 110mm evaluation unit HK4 NIR-4BFR
functionality / sensor systems 1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / reflection
NIR-4SFR
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / reflection
NIR-4BFT
1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / transmission
NIR-4SFT
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / transmission
NIR-4BTR
1 NIR-sensor halogen lamp 4B black enodized 3A-tankcell DN50 / reflection
NIR-4BTR
1 NIR-sensor halogen lamp 4S stainless steel 3A-tankcell DN50 / reflection
copyright Harrer & Kassen GmbH 2007
18
all rights reserved
Harrer & Kassen
2.3.3
HK4-3
Catalogue 2007-04
HK4-30
range of application Measurement in % of 5 organic constituents, through spectral absorption of all molecules of the CH-, NH- and OHcompounds. spectral range 1700nm - 2500nm design aluminium pressure casting housing h x w x d: 230 x 280 x 110mm evaluation unit HK4 NIR-4BFR
functionality / sensor systems 1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / reflection
NIR-4SFR
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / reflection
NIR-4BFT
1 NIR-sensor halogen lamp 4B black enodized 3A-flowcell DN50 / transmission
NIR-4SFT
1 NIR-sensor halogen lamp 4S stainless steel 3A-flowcell DN50 / transmission
NIR-4BTR
1 NIR-sensor halogen lamp 4B black enodized 3A-tankcell DN50 / reflection
NIR-4BTR
1 NIR-sensor halogen lamp 4S stainless steel 3A-tankcell DN50 / reflection
copyright Harrer & Kassen GmbH 2007
19
all rights reserved
Harrer & Kassen
2.3.4
Catalogue 2007-04
HK4-mobile-LAB HK4-ML
NIR-0001
range of application Measurement in % of 5 organic constituents, through spectral absorption of all molecules of the CH-, NH- and OHcompounds. spectral range 1700nm - 2500nm design aluminium-case h x w x d: 380 x 580 x 240mm HK4-mobile-LAB integrated: - HK4-3 evaluation unit - NIR-sensor / reflection - optical fiber - arrangement for petri dishes - notebook - chemometric software SPECTER - precalibrated product characteristics - measure Kit (for product preparation) - petri dishes (glassware) - operating manual evaluation unit HK4-3
2.4
HK5
HK5
range of application Measurement of moisture in thin layers at the production of - paper, card board (paper industry) - chip boards, veneers (primary industry)
design aluminium pressure casting housing h x w x d: 200 x 230 x 110mm standard cable (option max. 100m) evaluation unit HK5 functionality / sensor systems 2 sensors HK5-12 HK5-12
copyright Harrer & Kassen GmbH 2007
GHZ-0010 GHZ-0024
20
10 GHz-sensors 24 GHz-sensors
all rights reserved
Harrer & Kassen
Catalogue 2007-04
4 sensors HK5-14 HK5-14
GHZ-0010 GHZ-0024
10 GHz-sensors
HK5-16 HK5-16
GHZ-0010 GHZ-0024
10 GHz-sensors
HK5-18 HK5-18
GHZ-0010 GHZ-0024
10 GHz-sensors
24 GHz-sensors
6 sensors 24 GHz-sensors
8 sensors
copyright Harrer & Kassen GmbH 2007
21
24 GHz-sensors
all rights reserved
Harrer & Kassen
Catalogue 2007-04
2.5
HK6 Latest digital microwave technilogy at 2,45 GHz. The microwave instrument HK6 is available in 2 product versions: - HK6-C compact - HK2-F field
2.5.1
HK6-C
HK6-C1
range of application concentration measurement BRIX in the sugarindustry
design aluminium pressure casting housing h x w x d: 130 x 200 x 90mm
evaluation unit HK6-C functionality / sensor systems 2 integrated pinantennas PAN-6506
2.5.2
HK6-F
pinantennas (with NTC and flange DN65)
HK6-F1
range of application concentration measurement BRIX in the sugarindustry
design aluminium pressure casting housing h x w x d: 130 x 200 x 90mm no softkeys evaluation unit HK6-F functionality / sensor systems 2 integrated pinantennas pinantennas (with NTC and flange DN65)
OPE-6506
1 remote control remote control with 10m connection cable
copyright Harrer & Kassen GmbH 2007
22
all rights reserved
Harrer & Kassen
3 3.1 3.1.1
Catalogue 2007-04
Components sensors / antennas PT100 HKA-TE range of application Temperature acquisition of the product to compensate the measure result. in use with: - HK1-M - HK1-Mp - HK1-C - HK4
PT100-cable PT1-0100
PT2-E100
3.1.2
pinantennas
design length: ca.200mm thread: M8 standard cable 2,5m with connection electronic
HKA-MW
range of application Microwavemeasurement TS (total solids) in pipes and tanks.
pinantennas with flange
design
PAN-6506
PAN-8006
copyright Harrer & Kassen GmbH 2007
23
immersion depth 195mm flange DN65 in use with: - HK1-M - HK2-M - HK2-C - HK2-F - HK6-C - HK6-F immersion depth 195mm flange DN80 in use with: - HK1-M - HK1-Mp - HK1-C
all rights reserved
Harrer & Kassen
3.1.3
Catalogue 2007-04
pinantennas with cleaning HKA-MW
range of application Microwavemeasurement TS (total solids) in pipes and tanks. BRIX-measurement in the sugarindustry.
design
pinantennas with cleaning
PAC-6506
3.1.4
immersion depth 195mm flange DN65 in use with: - HK2-M
3A-spiralantennas HKA-MW
range of application Microwavemeasurement TS (total solids) in pipes.
3A-spiralantenna
design 3SA-3AFC
3.1.5
distance max. 200mm in use with: - HK1-M - HK1-Mp
short 3A-pinantennas HKA-MW
range of application Microwavemeasurement TS (total solids) in pipes.
short 3A-pinantenna
design 3SP-FLC1
copyright Harrer & Kassen GmbH 2007
24
distance max. 80mm in use with: - HK1-M
all rights reserved
Harrer & Kassen
3.1.6
Catalogue 2007-04
mini-spiralantennas HKA-MW
range of application Microwavemeasurement TS (total solids) in pipes.
Kurze 3A-Stabsensoren design mini-spiralantenna
3.1.7
MSA-FLC2
distance max. 200mm in use with: - HK1-M - HK1-Mp
spiralantennas HKA-MW
range of application Microwavemeasurement TS (total solids) at conveyer belts or arrangements with hand operated product supply
design spiralantenna SPA-0000
3.1.8
distance max. 500mm in use with: - HK1-M - HK1-Mc
hornantennas HKA-MW
range of application Microwavemeasurement TS (total solids) at conveyer belts.
design hornantenna HOA-0000
copyright Harrer & Kassen GmbH 2007
25
distance max. 1000mm in use with: - HK1-M
all rights reserved
Harrer & Kassen
3.1.9
Catalogue 2007-04
10/24GHz-sensors HKA-MW
range of application Microwavemeasurement TS (moisture) in thin layers (paper, card board, chip boards) on conveyer belts.
design 10/24GHz-sensors
3.1.10
GHZ-0010
10 GHz-version in use with: - HK5
GHZ-0024
24 GHz-version in use with: - HK5
NIR-sensor / halogenlamp HKA-IR
range of application NIR-reflection- oder -transmission measurement to detect organic molecules in CH-, NH- and OH-compounds.
design NIR-sensor
NIR-4BT1 NIR-4ST1 NIR-4BR1 NIR-4SR1
4 halogen bulbs / housing black enodized transmission measurement 4 halogen bulbs / housing stainless steel transmission measurement 4 halogen bulbs / housing black enodized reflection measurement 4 halogen bulbs / housing stainless steel reflection measurement in use with: - HK4
copyright Harrer & Kassen GmbH 2007
26
all rights reserved
Harrer & Kassen
3.2 3.2.1
Catalogue 2007-04
Measure cells 3A-flowcell (for 3A-spiralantennas) HKC-PR
range of application Microwavemeasurement TS (total solids) in pipes.
design 3A-flowcell
3SA-3AFC
pipe diameter DN50 in use with: - 3A-spiralantennas
2 welding flanges (for 3A-spiralantennas) HKC-PR
3SA-WFL1
3.2.2
pipe diameter DN100 or larger in use with: - 3A-spiralantennas
3A-flowcell (for short 3A-pinantennas) HKC-PR
range of application Microwavemeasurement TS (total solids) in pipes.
design 3A-flowcell
3SP-FLC1
pipe diameter DN50 in use with: - short 3A-pinantennas
2 welding sockets stainless steel (for short 3A-pinantennas) HKC-PR
3SP-WSO3 welding in pipes DN50 or larger
in use with: - short 3A-pinantennas copyright Harrer & Kassen GmbH 2007
27
all rights reserved
Harrer & Kassen
3.2.3
Catalogue 2007-04
flowcell (for mini-spiralantennas) HKC-NO
range of application Microwavemeasurement TS (total solids) in pipes.
design flowcell MSA-FLC2
pipe diameter DN65 in use with: - mini-spiralantennas
2 welding sockets stainless steel (for mini-spiralantennas) HKC-NO
MSA-WSO1 welding in pipes DN65 or larger
in use with: - mini-spiralantennas
3.2.4
3A-flowcell (for NIR-reflection) HKC-PR
range of application NIR-reflection measurement to detect organic molecules in CH-, NH- and OHcompounds.
design 3A-flowcell NIR-3AFR
pipe diameter DN50 in use with: - NIR-sensor/reflection
HKA-IR- NIR-4BR1 HKA-IR- NIR-4SR1
copyright Harrer & Kassen GmbH 2007
28
all rights reserved
Harrer & Kassen
3.2.5
Catalogue 2007-04
3A-flowcell (for NIR-transmission) HKC-PR
range of application NIR-transmission measurement to detect organic molecules in CH-, NH- and OHcompounds.
design Durchfluss-Messzelle NIR-3AFT
pipe diameter DN50 in use with: - NIR-sensor/transmis.
HKA-IR- NIR-4BT1 HKA-IR- NIR-4ST1
3.2.6
3A-tankcell (for NIR-reflection) HKC-PR
range of application NIR-reflection measurement to detect organic molecules in CH-, NH- and OHcompounds.
design 3A-tankcell NIR-3ATR
flange in use with: - NIR-sensor/reflection
HKA-IR- NIR-4BR1 HKA-IR- NIR-4SR1
copyright Harrer & Kassen GmbH 2007
29
all rights reserved
Harrer & Kassen
4 4.1 4.1.1
Catalogue 2007-04
Devices / Spareparts devices remote control HKD-OD range of application remote operation of HK-evaluation-units via 10m connection cable in use with: - HK1-M - HK1-Mp - HK1-C - HK2-M - HK2-C
OPE-0010
4.1.2 4.1.2.1
cable HF-cable
-
HK2-F HK5 HK6-C HK6-F
design plastic housing keypad / softkeys connection cable 10m
HKD-CA
range of application connection of modular microwave evaluation-units with sensors in use with: - HK1-M - HK1-Mp - HK1-Mc - HK2-M
HFC-0001 HFC-0002
4.1.2.2
design 1m coax cable/indoor and outdoor 2m max.
standard cable HKD-CA range of application cable for power supply
connection with sensors: - HK5
STA-0001 STA-0100
copyright Harrer & Kassen GmbH 2007
30
design 1m NYM-cable/indoor and outdoor 100m max.
all rights reserved
Harrer & Kassen
4.1.2.3
optical fiber
Catalogue 2007-04
HKD-OF
range of application connection of HK4-spectrometers with NIR-sensors in use with: - HK4
NIR-0001 NIR-0100
4.1.3
swiffle-flange
design 1m
optical fiber/indoor and outdoor with stainless steel coating 100m max.
HKD-FL
range of application adjustable device for pinantennas. optional spin of pinantennas. in use with: - pinantennas
4.1.4
PAN-0065
design DN65
PAN-0080
DN80
stainless steel box range of application housing for the protected installation of evaluation-unit and PS for distancelasersensor.
HKD-CH
in use with: - HK1-Mc
BOX-0001
4.1.5
design h x w x d: 300 x 500 x 167mm stainless steel
distance-lasersensor range of application rating of the thickness of the poduct (cheese/curd)
HKD-CH
in use with: - HK1-Mc
LAS-0001
copyright Harrer & Kassen GmbH 2007
31
design h x w x d: 300 x 500 x 167mm
all rights reserved
Harrer & Kassen
4.1.6
Catalogue 2007-04
laboratory-measure-device range of application installation of the sensors for TSmeasurement (cheese/curd). Hand operated product supply.
HKD-CH
in use with: - HK1-Mc
TEF-0001
4.2 4.2.1
spareparts halogen bulbs
design h x w x d: 600 x 800 x 800mm stainless steel frame with teflon-board
range of application exchange/rebuild of halogenbulbs in the NIR-sensor
HKS-LA
in use with:: - HK4
NIR-0001 NIR-0004
copyright Harrer & Kassen GmbH 2007
32
design 1 halogenbulb 5V / 6,5W set von 4 halogenbulbs each 5V / 6,5W
all rights reserved
Harrer & Kassen
5
5.1
Catalogue 2007-04
Technische Daten
HK1-M measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
200 x 250 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact
x
quick-connection
1 HF-IN
1
HF-OUT
2 x N-plug sockets
2 computer-interface
RS232 or RS485 bidirectional
circular plug-in connector
4 digital-inputs
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
rating at conveyer belts
x
TS/bulk material
1%
sensorsystems pinantennas 195mm / DN65
x
pinantennas 195mm / DN80
x
3A-spiralantennas
x
short 3A-pinantennas
x
mini-spiralantennas
x
spiralantennas
x
hornantennas
x
ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
33
all rights reserved
Harrer & Kassen
5.2
Catalogue 2007-04
HK1-Mp measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
177 x 177 x 100mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact 1 HF-IN
1
quick-connection HF-OUT
2 computer-interface digital-inputs
2 x N-plug sockets RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65 pinantennas 195mm / DN80
x
3A-spiralantennas
x
short 3A-pinantennas mini-spiralantennas
x
spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
34
all rights reserved
Harrer & Kassen
5.3
Catalogue 2007-04
HK1-Mc measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
200 x 250 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact
x
quick-connection
1 HF-IN
1
HF-OUT
2 x N-plug sockets
2 computer-interface
RS232 or RS485 bidirectional
circular plug-in connector
4 digital-inputs
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
rating in pipes rating in tanks rating at conveyer belts
x
cyclic 250ms
TS/liquids
0,2%
TS/liquids
0,2%
TS/bulk material
1%
sensorsystems pinantennas 195mm / DN65 pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas
x
hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
35
all rights reserved
Harrer & Kassen
5.4
Catalogue 2007-04
HK1-C measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
177 x 177 x 100mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact 1 HF-IN
1
quick-connection HF-OUT
2 computer-interface digital-inputs
2 x N-plug sockets RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65 pinantennas 195mm / DN80
x
3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
36
all rights reserved
Harrer & Kassen
5.5
Catalogue 2007-04
HK2-M measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
177 x 177 x 100mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100 1 relay contact 1 HF-IN
1
HF-OUT
2 computer-interface digital-inputs
NTC
quick-connection
x
quick-connection
2 x N-plug sockets RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65
x
option: sensor cleaning
pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
37
all rights reserved
Harrer & Kassen
5.6
Catalogue 2007-04
HK2-C measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
177 x 177 x 100mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100 1 relay contact 1 HF-IN
1
HF-OUT
2 computer-interface digital-inputs
NTC
quick-connection
x
quick-connection
2 x N-plug sockets RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65
x
pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
38
all rights reserved
Harrer & Kassen
5.7
Catalogue 2007-04
HK2-F measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
177 x 177 x 100mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100 1 relay contact 1 HF-IN
1
HF-OUT
2 computer-interface digital-inputs
NTC
quick-connection
x
quick-connection
2 x N-plug sockets RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65
x
pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
39
all rights reserved
Harrer & Kassen
5.8
Catalogue 2007-04
HK4-1 measuring method
NIR-spectrometer with diodearray
housing
aluminium pressure casting housing
dimensions h x w x d
230 x 280 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply 3 analog outputs 1 PS-halogenlamp
various 100-240V / AC
quick-connection
0/4 - 20mA
quick-connection
x
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact
x
quick-connection
1 optical fiber
1 connection
2 computer-interfaces
RS232 or RS485 bidirectional
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
spectral range
600nm - 1100nm
rating in pipes
CH-/NH-/OH-compounts
assortments / powder
0,5%
rating in tanks
CH-/NH-/OH-compounts
assortments / powder
0,5%
rating at jiggle chuts
CH-/NH-/OH-compounts
powder
0,5%
sensorsystems NIR-sensor reflection
x
NIR-sensor transmission
x
calibration and commissioning
chemometric software SPECTER
ambient conditions environment temperature
-20°C - +45°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
40
all rights reserved
Harrer & Kassen
5.9
Catalogue 2007-04
HK4-2 measuring method
NIR-spectrometer with diodearray
housing
aluminium pressure casting housing
dimensions h x w x d
230 x 280 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply 4 analog outputs 1 PS-halogenlamp
various 100-240V / AC
quick-connection
0/4 - 20mA
quick-connection
x
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact
x
quick-connection
1 optical fiber
1 connection
2 computer-interfaces
RS232 or RS485 bidirectional
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
spectral range
1200nm - 1700nm
rating in pipes
CH-/NH-/OH-compounts
assortments / powder
0,1%
rating in tanks
CH-/NH-/OH-compounts
assortments / powder
0,1%
rating at jiggle chuts
CH-/NH-/OH-compounts
powder
0,1%
sensorsystems NIR-sensor reflection
x
NIR-sensor transmission
x
calibration and commissioning
chemometric software SPECTER
ambient conditions environment temperature
-20°C - +45°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
41
all rights reserved
Harrer & Kassen
5.10
Catalogue 2007-04
HK4-3 measuring method
NIR-spectrometer with diodearray
housing
aluminium pressure casting housing
dimensions h x w x d
230 x 280 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply 5 analog outputs
various 100-240V / AC
quick-connection
0/4 - 20mA
1 PS-halogenlamp
quick-connection
x
quick-connection
1 temperature/PT100
x
quick-connection
1 relay contact
x
quick-connection
1 optical fiber
1 connection
2 computer-interfaces
RS232 or RS485 bidirectional
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
spectral range
1700nm - 2500nm
rating in pipes
CH-/NH-/OH-compounts
assortments / powder
0,1%
rating in tanks
CH-/NH-/OH-compounts
assortments / powder
0,1%
rating at jiggle chuts
CH-/NH-/OH-compounts
powder
0,1%
sensorsystems NIR-sensor reflection
x
NIR-sensor transmission
x
calibration and commissioning
chemometric software SPECTER
ambient conditions
5.11
environment temperature
-20°C - +45°C
product temperature
>0°C - +130°C
HK4-mobile-LAB measuring method
NIR-spectrometer with diodearray
housing evaluation unit
aluminium pressure casting housing
dimensions h x w x d
230 x 280 x 110mm
protection class
IP65
weight colour aluminium-case h x w x d
RAL 5024 380 x 580 x 240mm
circuit points power supply
various 100-240V / AC
quick-connection
5 analog values 1 PS-halogenlamp 1 notebook
x
1 measure Kit
x
1 chemometric software
x
SPECTER
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning rating in petri dishes
copyright Harrer & Kassen GmbH 2007
spektral range
1700nm - 2500nm
CH-/NH-/OH-compounds
asortments / powders
42
0,1%
all rights reserved
Harrer & Kassen
5.12
Catalogue 2007-04
HK5 measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
200 x 230 x 110mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
110/230V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
quick-connection
1 relay contact
quick-connection
2 sensor-plugs
standardcable
2 computer-interfaces
RS232 or RS485 bidirectional
circular plug-in connector
ext. select:16 products/on/off
circular plug-in connector
digital-inputs
quick-connection
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
rating in pipes rating in tanks rating at conveyer belts
x
cyclic 250ms
TS/liquids
0,2%
TS/liquids
0,2%
TS/thin layers
0,2%
sensorsystems pinantennas 195mm / DN65 pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas 10/24GHz-sensors
x
ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
43
all rights reserved
Harrer & Kassen
5.13
Catalogue 2007-04
HK6-C measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
130 x 200 x 90mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
various 100-240V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
NTC
quick-connection
1 relay contact 1 HF-IN
1
quick-connection HF-OUT
2 x N-plug sockets
2 computer-interface
RS232 or RS485 bidirectional
circular plug-in connector
4 digital-inputs
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65
x
pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
44
all rights reserved
Harrer & Kassen
5.14
Catalogue 2007-04
HK6-F measuring method
microwavetechnique 2,45 GHz
housing
aluminium pressure casting housing
dimensions h x w x d
130 x 200 x 90mm
protection class
IP65
weight colour
RAL 5024
circuit points power supply
various 100-240V / AC
quick-connection
2 analog output
0/4 - 20mA
quick-connection
1 analog intput
0/4 - 20mA
quick-connection
1 temperature/PT100
NTC
quick-connection
1 relay contact 1 HF-IN
1
quick-connection HF-OUT
2 x N-plug sockets
2 computer-interface
RS232 or RS485 bidirectional
circular plug-in connector
4 digital-inputs
ext. select:16 products/on/off
circular plug-in connector
user interface operating
6 softkeys in integrated keypad
monitoring
2 x 24 characters in illuminated display
measuring accuracy / scanning
analog/digital-conversion
cyclic 250ms
rating in pipes
x
TS/liquids
0,2%
rating in tanks
x
TS/liquids
0,2%
TS/bulk material
1%
rating at conveyer belts sensorsystems pinantennas 195mm / DN65
x
pinantennas 195mm / DN80 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas ambient conditions environment temperature
-20°C - +85°C
product temperature
>0°C - +130°C
copyright Harrer & Kassen GmbH 2007
45
all rights reserved
Harrer & Kassen
6
Catalogue 2007-04
Operation / Commissioning In the plants, our instruments are in operation permanently, i.e. independent from the status of the engineering process. This can be normal operation, start up, shut down or standstill.
The microwave instruments are designd for ambient temperatures of about >0°C to +85°C The NIR-spectrometer is designed for ambient temperatures of about >0°C to +45°C For both measuring devices the temperature range of the to be rated product is >0°C to +130°C The measuring instruments provides the rated values as standard-analogsignals (0/4 - 20mA) for the further processing in superposed open-loop-, closed-loop or controlsystems. The measuring instruments can be pre-calibrated for different product-lines, the change from product 1 to product 2 is effected by manual operation or by the superposed system. The manual fine-tuning of the setted parameters in the microwave-instruments occurs with the user interface of the evaluation unit. The user interface of each evaluation unit is menue controlled. This is realized by softkeys with a keypad control. This means, that the softkeys below the display with 2 x 24 characters have a different relevance in dependance of the status of operation.
copyright Harrer & Kassen GmbH 2007
46
all rights reserved
Harrer & Kassen
Catalogue 2007-04
The NIR-spectrometer performs the same user-interface with the evaluation unit. But in the online-mode it is used only for displaying the current values. Adjustments of parameters or the calibration of new products is performed with
the chemometric software SPECTER. Productspecific calibrations of samples are stored in a database and can be used as references for new and further calibrations.
Engineering: The know-how for the technical layout of our measuring equipment is the intellectual property of Harrer & Kassen GmbH. By the planning of microwavesystem the dependences of antenna distance, product temperature and pipe diameter is only one example for many engineering steps, which have to be executed. By the planning of NIR-equipments nothing has the importance, in addition to the accuracy of spectroscopy and calibration, like the location of the glass window. Together with our clients we work out the only reasonable and efficient solutions. Installation: For all sensorsystems of our measuring equipments regulations for installation are worked out. The required mechanical devices like welding-sockets or -flanges are in the scope of supply of the measuring equipment and delivered by us. Normally the client takes responsibility of the mounting. Commissioning: For each of our measurement instruments a manual is available. In detail every step of commissioning is explained. The commissioning is also an option in our offers and can be executed by us. We also offer professional trainings, to make sure, that our clients have the capability to provide commissioning, calibration and process operation on their own.
copyright Harrer & Kassen GmbH 2007
47
all rights reserved
Harrer & Kassen
Catalogue 2007-04-A6
7
Article Numbers / Pricelist 2007-04-A6
7.1
HK1
article number 7.1.1
EUR
HK1-M evaluation-unit with 2x2m HF-cable pinantennas (with PT100 and flange DN65) 2
HK1-M1PAN-
6506
2
pinantennas (with PT100 and flange DN80)
PAN-
8006
2
3A-spiralantennas (for 3A-flowcell**)
3SA-
3AFC
2
short 3A-pinantennas (for 3A-flowcell**)
3SP-
FLC1
2
mini-spiralantennas with sockets (for flowcell**)
MSA-
FLC2
**not included in the delivery range
evaluation-unit with 2x2m HF-cable
7.1.2
HK1-M2-
2
spiralantennas
SPA-
0000
2
hornantennas
HOA-
0000
HK1-Mp evaluation-unit with 2x2m HF-cable pinantennas (with PT100 and flange DN80) 2
HK1-MPPAN-
8006
2
3A-spiralantennas (for welding-flanges**)
3SA-
WFL1
2
mini-spiralantennas with sockets (for flowcell**)
MSA-
FLC2
SPA-
CH01
LAB-
CH02
PAN-
8006
PAN-
6506
PAN-
6516
PAN-
6506
OPE-
6506
**not included in the delivery range
7.1.3
HK1-Mc evaluation-unit with 2x2m HF-cable 2
HK1-MC-
spiralantennas incl. 1 stainless steel housing incl. 1 "distance-lasersensor" with PS and cables
7.1.4
HK1-Mc-LAB evaluation-unit with 2x2m HF-cable 2
HK1-MC-
spiralantennas incl. 1 laboratory-device (stainless steel/teflon) incl. 1 "distance-lasersensor" with PS and cables
7.1.5
HK1-C evaluation-unit pinantennas 195mm (with PT100 and flange DN80) 2
7.2
HK2
7.2.1
HK2-M evaluation-unit with 2x2m HF-cable pinantennas (flange DN65) 2 2
7.2.2
HK2-M1-
pinantennas (with cleaning and flange DN65)
HK2-C evaluation-unit pinantennas 195mm (with NTC and flange DN65) 2
7.2.3
HK1-C1-
HK2-C1-
HK2-F evaluation-unit without softkeys pinantennas (with NTC and flange DN65) 2 1
HK2-F1-
operating-device (with 10m connection-cable)
copyright Harrer & Kassen GmbH 2007
48/pl1
all rights reserved
Harrer & Kassen
Catalogue 2007-04-A6
article number
7.3 7.3.1
EUR
HK4 HK4-1 evaluation-unit 600nm-1100nm / 3C / 0,5% NIR-sensor 4B (with 3A-flowcell DN50 / reflexion) 1
HK4-10NIR-
4BFR
1
NIR-sensor 4S (with 3A-flowcell DN50 / reflexion)
NIR-
4SFR
1
NIR-sensor 4B (with 3A-flowcell DN50 / transmission)
NIR-
4BFT
1
NIR-sensor 4S (with 3A-flowcell DN50 / transmission)
NIR-
4SFT
1
NIR-sensor 4B (with 3A-tank-cell DN50 / reflexion)
NIR-
4BTR
1
NIR-sensor 4S (with 3A-tank-cell DN50 / reflexion)
NIR-
4STR
(1-4 halogen-bulbs / B black enodized / S stainless steel)
7.3.2
HK4-2 evaluation-unit 1200nm-1700nm / 4C / 0,1% NIR-sensor 4B (with 3A-flowcell DN50 / reflexion) 1
HK4-20NIR-
4BFR
1
NIR-sensor 4S (with 3A-flowcell DN50 / reflexion)
NIR-
4SFR
1
NIR-sensor 4B (with 3A-flowcell DN50 / transmission)
NIR-
4BFT
1
NIR-sensor 4S (with 3A-flowcell DN50 / transmission)
NIR-
4SFT
1
NIR-sensor 4B (with 3A-tank-cell DN50 / reflexion)
NIR-
4BTR
1
NIR-sensor 4S (with 3A-tank-cell DN50 / reflexion)
NIR-
4STR
(1-4 halogen-bulbs / B black enodized / S stainless steel)
7.3.3
HK4-3 evaluation-unit 1700nm-2500nm / 5C / 0,1% NIR-sensor 4B (with 3A-flowcell DN50 / reflexion) 1
HK4-30NIR-
4BFR
1
NIR-sensor 4S (with 3A-flowcell DN50 / reflexion)
NIR-
4SFR
1
NIR-sensor 4B (with 3A-flowcell DN50 / transmission)
NIR-
4BFT
1
NIR-sensor 4S (with 3A-flowcell DN50 / transmission)
NIR-
4SFT
1
NIR-sensor 4B (with 3A-tank-cell DN50 / reflexion)
NIR-
4BTR
1
NIR-sensor 4S (with 3A-tank-cell DN50 / reflexion)
NIR-
4STR
(1-4 halogen-bulbs / B black enodized / S stainless steel)
7.3.4
HK4-mobile-LAB
HK4-ML- NIR
0001
evaluation-unit 1700nm-2500nm / 5C / 0,1% NIR-sensor 4B (reflexion) 1 1
notebook (with SPECTER-software)
1
measure-kit
7.4
HK5
7.4.1
HK5-1 evaluation-unit
7.4.2
10/24GHz
HK5-12-
2
10GHz-sensors
GHZ-
0010
2
24GHz-sensors
GHZ-
0024
HK5-2 evaluation-unit
10/24GHz
HK5-14-
4
10GHz-sensors
GHZ-
0010
4
24GHz-sensors
GHZ-
0024
copyright Harrer & Kassen GmbH 2007
49/pl2
all rights reserved
Harrer & Kassen
Catalogue 2007-04-A6
article number 7.4.3
evaluation-unit
7.4.4
10/24GHz
HK5-16-
6
10GHz-sensors
GHZ-
0010
6
24GHz-sensors
GHZ-
0024
HK5-4 evaluation-unit
10/24GHz
HK5-18-
8
10GHz-sensors
GHZ-
0010
8
24GHz-sensors
GHZ-
0024
PAN-
6506
OPE
6506
7.5
HK6
7.5.1
HK6-C evaluation-unit pinantennas 195mm (with NTC and flange DN65) 2
7.5.1
HK6-C1-
HK6-F evaluation-unit without softkeys pinantennas 195mm (with NTC and flange DN65) 2 1
HK6-F1-
operating-device (with 10m connection-cable)
7.6
components
7.6.1
evaluation-units
7.6.2
EUR
HK5-3
1
HK1-M
HK1-M1- XXX-
0000
1
HK1-Mp
HK1-MP- XXX-
0000
1
HK2-M
HK2-M1- XXX-
0000
1
HK5
HK5-00- XXX-
1224
sensors / antennas 1
PT100
HKA-TE- PT1-
0100
1
PT100 plus connection-electronic
HKA-TE- PT2-
E100
2
pinantennas 195mm / DN65
HKA-MW- PAN-
6506
2
pinantennas 195mm / DN80
HKA-MW- PAN-
8006
2
pinantennas 195mm / DN65 / cleaning
HKA-MW- PAC-
6506
2
3A-spiralantennas
HKA-MW- 3SA-
3AFC
2
short 3A-pinantennas
HKA-MW- 3SP-
FLC1
2
mini-spiralantennas
HKA-MW- MSA-
FLC2
2
spiralantennas
HKA-MW- SPA-
0000
2
hornantennas
HKA-MW- HOA-
0000
2
12GHz-sensors
HKA-MW- GHZ-
0012
2
24GHz-sensors NIR-sensor 4B (4 halogen-bulbs/body black enodized/transmission)
HKA-MW- GHZ-
0024
1
HKA-IR-
NIR-
4BT1
1
NIR-sensor 4S
(4 halogen-bulbs/body stainless steel/transmission)
HKA-IR-
NIR-
4ST1
1
NIR-sensor 4B
(4 halogen-bulbs/body black enodized/reflexion)
HKA-IR-
NIR-
4BR1
1
NIR-sensor 4S
(4 halogen-bulbs/body stainless steel/reflexion)
HKA-IR-
NIR-
4SR1
copyright Harrer & Kassen GmbH 2007
50/pl3
all rights reserved
Harrer & Kassen
Catalogue 2007-04-A6
article number 7.6.3
cells 3A-flowcell DN50 (for 3A-spiralantennas) 1
EUR
HKC-PR- 3SA-
3AFC
1
3A-flowcell DN50 (for short 3A-pinantennas)
HKC-PR- 3SP-
FLC1
1
flowcell (for mini-spiralantennas) on request
HKC-NO- MSA-
FLC2
2
welding flanges stainless steel (for 3A-spiralantennas)
HKC-PR- 3SA-
WFL1
2
welding sockets stainless steel (for short 3A-pinantennas)
HKC-PR- 3SP-
WSO3
2
welding sockets stainless steel (for mini-spiralantennas)
HKC-NO- MSA-
WSO1
1
3A-flowcell DN50 (for NIR-reflexion)
HKC-PR- NIR-
3AFR
1
3A-flowcell DN50 (for NIR-transmission)
HKC-PR- NIR-
3AFT
1
3A-tank-cell DN50 (for NIR-reflexion)
HKC-PR- NIR-
3ATR
all other diameters and special manufactures on request
7.7
devices / spare parts
7.7.1
devices operating-device (with 10m connection-cable) 1
HKD-OD- OPE-
0010
1
HF-cable
1m
HKD-CA- HFC-
0001
1
HF-cable
2m
HKD-CA- HFC-
0002
1
standard-cable
1m *
HKD-CA- STA-
L001
1
standard-cable
100m *
HKD-CA- STA-
L100
1
optical fiber
1m *
HKD-OF- NIR-
L001
1
optical fiber
100m *
HKD-OF- NIR-
L100
1
swiffle-flange DN65
HKD-FL- PAN-
0065
1
swiffle-flange DN80
HKD-FL- PAN-
0080
1
stainless steel housing (300x500x167mm)
HKD-CH- BOX-
0001
1
"distance-lasersensor" incl. PS and cables laboratory-device (stainless steel/teflon) for HK1-Mc
HKD-CH- LAS-
0001
HKD-CH- TEF-
0001
monitoring-software for HK4-applications
HKD-SW- MON-
A001
1 1
*lengths in full meters free selectable
7.7.2
spare parts 1
halogen-bulb
HKS-LA- NIR-
0001
1
set with 4 halogen-bulbs
HKS-LA- NIR-
0004
HKF-CO- MW1-
0001
HKF-CO- MW2-
0001
HKF-CO- NIR-
0001
HKF-CA- NIR-
0001
7.8
services
7.8.1
commissioning COM (in Germany) 1
1 1 7.8.2
COM-MW
COM-MW COM-NIR
HK1-M1-
HK1-MP-
HK1-C1-
HK2-M1
HK2-C1
HK2-F1
HK6-C1
HK6-F1
HK1-M2-
HK1-MC-/LAB HK5-12
HK5-14
HK5-16
HK5-18
HK4-10
HK4-20
HK4-30
preparation for calibration (in-house) samplespectra-scanning (for 1 organic constituent)
1 7.8.3
training (in-house) 1
training operating personnel
microwave-systems/3 persons
HKT-TE- MWT-
0001
1
training operating personnel
NIR-spectrometer/3persons
HKT-TE- NIR-
0001
copyright Harrer & Kassen GmbH 2007
51/pl3
all rights reserved
Harrer & Kassen
8
Catalogue 2007-04
Conditions for Sale and Trade / Imprint For Harrer & Kassen GmbH the General Business Conditions of the German Electro Industry are valid for Product Developement and Sales.
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
Tel: Fax:
0049 (0)7084 9248-0 0049 (0)7084 9248-29
eMail: web:
[email protected] www.harrerkassen.com
Horst Harrer Dipl.Ing. County Court Calw HRB829 DE144606035
General Management: Commercial Trade Register: VAT-Identification:
Responsible for the editorial and contents: Ulrich Ottenburger Dipl.Ing. Marketing and Sales Harrer & Kassen GmbH Tel: eMail:
0049 (0)7084 9248-15
[email protected]
copyright Harrer & Kassen GmbH 2007
52
all rights reserved
Harrer & Kassen
9
Catalogue 2007-04
Technical Annex
Technical dimension- and datasheets > > > > > > > > > > > > > > > >
HK1-M HK1-Mp HK1-Ca HK1-Cb HK2-M HK2-Ca HK2-Cb HK2-Fa HK2-Fb HK4a HK4b HK5 HK6-Ca HK6-Cb HK6-Fa HK6-Fb
> > > > > > > > > > >
PT100 pinantennas 195mm / DN65 pinantennas 195mm / DN80 pinantennas / cleaning 3A-spiralantennas short 3A-pinantennas mini-spiralantennas spiralantennas hornantennas 10/24GHz-sensors NIR-sensor 4B
> > > > >
3A-flowcell (for 3A-spiralantennas/NIR-reflection/-transmission) 3A-flowcell (for short 3A-pinantennas) and welding sockets flowcell (for mini-spiralantennas) and welding sockets (a) flowcell (for mini-spiralantennas) and welding sockets (b) 3A-tankcell (for NIR-reflection)
> > > >
remote control (operating device) HF-cable standard cable optical fiber
> swiffle flange DN65 > swiffle flange DN80
copyright Harrer & Kassen GmbH 2007
53
all rights reserved
5
10
Power
15
Current Input
AC 230V
20
30
35
40
45
50
2xRS232- Interface
0/4-20mA
GND
AC 110V
TX2
- +
5
25
RX2
RX1 GND
5V
HF-OUT
TX1 110mm
Current outputs
10
180mm 15
230mm
L1 GND
N
Relay
Input Temperature
D1 D2
D3D4GND
Product Select
HF-IN
20
200mm 250mm
Housing 230 x 200x 110mm 30
HK1-M evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK1-M1-XXX-0000 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
Analog Outputs 2x0/4-20mA
I1 I2 + - + - RX1 5
TX1
2xRS232-Interface TX2 RX2
5V
10
HF-OUT
Power
GND
100mm
HK1-Mp (paper)
177
AC230V AC11OV
L1 HF-IN
N 15 GND GND External Temperature input (PT 100) 20
HK1-Mp (paper) Modular Microwave Gauge with Display and Keyboard for connecting any kind of Sensor ia two HF-cables 177mm Standard-Features -Voltage: 239V +/-15%, 47-65HZ -Analog current output for process value, 0/4-20mA, load resistance 500Ohm
Options:
-Two HF-cables
-Voltage: 115V +/-15%, 47-65HZ
-Two RS 232 ports for data logging and remote control
-Remote control box
-Different kinds of Sensors or Antennas 30
-external temperature input PT100 -second current output for process value or temperature
HK1-Mp evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK1-MP-XXX-0000 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5 18mm
M10x1(PT100) 10 177mm
16mm
65mm
15
20 177mm 190mm
30
HK1-C evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK1-C1-PAN-8006 a 23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
100mm
30
35
40
45
50
193mm
90mm
5
2xRS232Interface 10
5V TX2 RX2 RX1 TX1 GND
Analog Output 15
2x0/4-20mA I2 (Option) Power
20
+ I2 + I1
GND
AC 230V
L1
AC 110V
N
Flange DN80 PN6
30
HK1-C evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK1-C1-PAN-8006 b 23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
Analog Outputs 2x0/4-20mA
I2 (Option)
I1 I2 + - + - RX1
5
TX1
2xRS232-Interface TX2 RX2
5V
10
HF-OUT
Power
GND
177
HK2-M 100mm
AC230V AC11OV
L1 HF-IN
N 15 GND Relay or external Temperature input (Option) 20
HK2-M Modular Microwave Gauge with Display and Keyboard for connecting any kind of Sensor via two HF-cables 177mm Standard Features -Voltage: 230V +/-15%, 47-65HZ
Options:
-Analog current output for process value, 0/4-20mA, load resistance 500Ohm
-Voltage: 115 +/-15%, 47-65HZ
-Two HF-cables
-Second current output for process value or temperature
-Two RS 232 ports for data logging or remote control
-Relay output for min and max measurement values to give an alarm
-Different kinds of Sensors or Antennas
-Relay output to control the cleaning times, when a sensor with cleaning
30
device is required -external temperature input PT100 or NTC -Remote control box
HK2-M evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK2-M1-XXX-0000 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
5
15
20
100mm
2xRS232 Interfaces
25
90mm
30
35
40
45
50
193mm
5V TX2 RX2 GND
15 Analog Outputs 2x0/4-20mA I2 (Option)
_ I2 + _ I1 +
20 Relay or external Temperature input (Option) GND
L1
N
Flange DN 65 PN6
Power AC 23OV AC 11OV 30
HK2-C evaluation-unit with pinantennas
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK2-C1-PAN-6506 a 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
14mm 14
10
HK2-C 16 16mm
160mm
177mm
50 50mm 15
20
177mm
30
HK2-C evaluation-unit with pinantennas
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK2-C1-PAN-6506 b 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
177mm 5
10
120mm 177mm 15
operating-device
20
200mm
30
HK2-F evaluation-unit with operating-device
HK2-F1-OPE-6506
a
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
100mm
20
25
30
35
90mm
40
45
50
193mm
5
1xRS23210
Schnittstellen
5V TX2 RX2
GND 15
Analog Ausgang 2x0/4-20mA I2 (Option) Power
20
I1 I2
+ + -
GND
AC 230V AC 110V
L1 N
30
HK2-F evaluation-unit with operating-device
HK2-F1-OPE-6506
b
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
Current Outputs 5
2x0/4-20mA PS halogenlamps
RS232- Interfaces Input Temperature
10
110mm 15
20
N
GND
L1
Power
Current Outputs
AC 230V AC 110V
30
HK4-1/-2/-3 evaluation-unit a
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
280mm 5
10
HK4
15
230mm
20
30
HK4-1/-2/-3 evaluation-unit b
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
230mm 5
10 110mm 200mm
HK5
15
20
30
HK5 evaluation-unit
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HK5-00-XXX-1224 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15 90mm
20
25
30
35
90mm
40
45
50
193mm
GND
5 Power
N
AC 100-230V
L1
50/60Hz 200mA Analog Output 10 I2(Option) 2x0/4-20mA
+ I1 I2 + TX2 RX2 5V
15 RS232- Interfaces CAN-BUS (Option) GND
GND Flange DN 65 PN6 Flansch DN65 PN6
20
Flange DN 65 PN6
30
HK6-C evaluation-unit with pinantennas
HK6-C1-PAN-6506
a
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5 200mm
14mm 10
HK6-C 16mm 15
130mm 50mm
20
30
HK6-C evaluation-unit with pinantennas
HK6-C1-PAN-6506
b
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15 90mm
20
25
30
35
90mm
40
45
50
193mm
GND
5 Power
N
AC 100-230V
L1
50/60Hz 200mA Analog Output 10 I2(Option) 2x0/4-20mA
+ I1 I2 + TX2 RX2 5V
15 RS232- Interfaces CAN-BUS (Option) GND
GND Flange DN 65 PN6 Flansch DN65 PN6
20
Flange DN 65 PN6
30
HK6-F evaluation-unit with pinantennas / without softkeys
HK6-F1-OPE-6506
a
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
14mm 14mm
10 16mm 16mm
160mm
120mm
50mm 50mm
15
operating device
20
200mm
30
HK6-F evaluation-unit with pinantennas / without softkeys
HK6-F1-OPE-6506
b
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
5
10
15
PT 100
HKA-TE-PT1-0100
(+connection-electronic)
with connection-electronic:
HKA-TE-PT2-E100
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
10
160mm 50mm 15
260mm 14mm
20
160mm ca. 260mm 195mm
30 Thread M18x1
PP-cover
HF-Connector
pinantennas 195mm/ DN65 HKA-MW-PAN-6506
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
M10x1 PT 100
10
22mm 190mm 65mm
15
260mm
16mm 20
190mm ca. 260mm 195mm
30 Thread M18x1
PP-cover
HF-Connector
pinantennas 195mm/ DN80 HKA-MW-PAN-8006
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
18
cleaning 10
145mm
50 15
20
185mm
30
pinantennas 195mm/ DN65/cleaning HKA-MW-PAC-6506
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
50mm 33mm 5
75mm 84mm
10 84mm 75mm
15
3A- spiralantenna HK-MW-3SA-3AFC
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
101mm ca.51mm
PP-Cover
30mm 5
SW 27 HF- Connector
Thread M18x1 Stainless Steel
30mm
30mm
10
PP-Cover
HF- Connector
15
short 3A-pinantenna HKA-MW-3SP-FLC1
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
34mm
5 78,5mm
31,2mm
34mm
10
15
mini-spiralantenna (for flowcell)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKA-MW-MSA-FLC2 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
25mm
D80mm
61mm 36mm
5 15mm
D6,8mm
100mm 74mm 84mm
10
15
10mm
10mm
spiralantenna HKA-MW-SPA-0000
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5 111mm 37mm
90mm
10
61,50mm 258mm
15 70mm 119mm
25mm
143mm 20
119mm 25
111mm
143mm
30
hornantenna HKA-MW-HOA-0000
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
160mm
30
35
40
45
50
160mm
5 58mm 10GHz-sensor
65mm
80mm 10
10GHz-sensor
15
160mm
160mm
20 58mm 24GHz-sensor
80mm
24GHz-sensor 30
10/24 GHz-sensor HK5-(12;14;16;18)GHZ-0010/0024
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
65mm
25
78mm
5
10
15
NIR-sensor 4B (4 halogen-bulbs/ body black enodized)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKA-IR-NIR-4BR1 23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5 50mm
10
180mm 57mm 15
20
3A-flowcell DN50:
article number:
50mm
30
3A-flowcell DN50 (for 3A-spiralantennas)
HKC-PR-3SA-3AFC
3A-flowcell DN50 (for NIR-reflexion)
HKC-PR-NIR-3AFR
3A-flowcell DN50 (for NIR-transmission)
HKC-PR-NIR-3AFT
3A-flowcell DN50 www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
30mm 5 30mm
57mm
51mm
10 57mm
250mm
15
20
75mm
welding sockets for short 3A-pinantennas:
30
22mm
22mm
44,6
3A-flowcell (for short 3A-pinantennas)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKC-PR-3SP-FLC1 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
35mm 31,4mm
welded seam
5 75mm
pipe
10 welding sockets stainless steel (for mini-spiralantennas): 34mm 31,2mm article number:
HKC-NO-MSA-WSO1
15
flowcell (for mini-spiralantennas)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKC-NO-MSA-FLC2 on request a 22.August 2006 ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
5
25
30
35
40
45
50
35mm
10
75mm 15
20 welding sockets stainless steel (for mini-spiralantennas): 34mm 31,2mm article number:
HKC-NO-MSA-WSO1
30
flowcell (for mini-spiralantennas)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKC-NO-MSA-FLC2 on request b 22.August 2006 ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
165mm 155mm 5
24,5mm 10
68mm
165mm
15
20
30
3A-tank-cell (for NIR-reflexion)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKC-PR-NIR-3ATR 23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5
10 120mm
15
200mm
20
200mm
30
operating-device (with 10m connecting-cable)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKD-OD-OPE-0010 23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
5
10
15
HF-cable 1m/2m HKD-CA-HFC-0001/0002
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
5
10
15
standard-cable (lengths in meters free selectable)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKD-CA-STA-L001/L100 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
5
10
15
optical fiber 1m/100m (lengths in meters free selectable)
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
HKD-OF-NIR-L001/L100 22.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
45
50
5 75mm
160mm
10
ca 110mm 15
14 20
81mm 160mm
30
swiffle-flange DN65 HKD-FL-PAN-0065
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot
Harrer & Kassen GmbH Am Heschen 6 D-75328 Langenbrand Germany
5
10
15
20
25
30
35
40
5
45
50
190mm 90mm
10
ca 130mm 15
18 20
94mm 190mm
30
swiffle-flange DN80 HKD-FL-PAN-0080
www.harrerkassen.com
copyright Harrer & Kassen GmbH / all rights reserved
23.August 2006
ot